Whatman Polycap TF capsule filters from GE Healthcare are made with durable, hydrophobic polytetrafluoroethylene (PTFE) membranes in a polyproplyene housing for use with organic solvents and chemically aggressive solutions.
Description
- PTFE filter membrane is resistant to most solvents
- Available in 0.1, 0.2, 0.45, and 1.0 µm pore sizes
- 1.0 µm pore size capsules used for extended life and filtration of highly contaminated solutions
- Manufactured according to ISO9001:2008 QMS standards
- Autoclavable capsule filtration device if sterility is required
GE Healthcare’s Life Sciences business offers a variety of Whatman Polycap filter options beyond PTFE filter membrane media.
Whatman Polycap filter for aggressive solvents
Filtration of organic solvents and aggressive solutions requires a durable membrane for filtration without sample contamination.
Autoclavable Polycap TF capsule filters feature PTFE membranes with high chemical resistance. Common applications include venting, in-line filtration to sterilize* and remove particles from air/gas/liquid streams, filtration to ensure clean inert gases in vial filling lines, and isolation of exhaust from fermenters.
Polycap TF filters support use in the electronics, pharmaceutical, and biopharmaceutical industries, because they are photoresistant and can be used to vent and perform in-line filtration for production systems in biological environments.
Parameter | Polycap TF 36 |
---|---|
Housing : | Polypropylene (PP) |
Operating pressure max. : | 4.1 bar (60 psi) |
Vent : | On inlet |
Flow Direction : | Supported bidirectionally. Certain applications may require orientation, i.e., vents. Reverse flow only for low pressure applications. |
Sterilization: | May be autoclaved at 121°C for 20 minutes. Multiple autoclave cycles are possible. However, the responsibility for reuse is with the operator. The device should be protected from cross contamination. An integrity test should be performed after autoclaving.Compatible with EtO sterilization. |
Sealing : | Heat-fused |
Support System : | Polypropylene (PP) |
Dimensions: | 36 mm |
Product Name : | Polycap TF 36, 0.1 µm, with MNPT inlet and 3/8 in SB outlet (1 pc)
Polycap TF 36, 0.2 µm, with 3/8 in SB inlet and outlet (1 pc) Polycap TF 36, 0.2 µm, with 1/2 in SB inlet and outlet (1 pc) Polycap TF 36, 0.2 µm, with MNPT inlet and 3/8 in SB outlet (1 pc) Polycap TF 36 Capsule Filter, 0.2 µm, with FNPT inlet and outlet (5 pcs) Polycap TF 36, 0.45 µm, with 1.5 in sanitary inlet and outlet (1 pc) Polycap TF 36, 0.45 µm, with MNPT inlet and 3/8 in SB outlet (1 pc) Polycap TF 36, 1.0 µm, with 3/8 in SB inlet and outlet (1 pc) Polycap TF 36, 1.0 µm, with FNPT inlet and outlet (5 pcs) |
Parameter | Polycap TF 75 |
---|---|
Housing : | Polypropylene (PP) |
Operating pressure max. : | 4.1 bar (60 psi) |
Vent : | On inlet |
Flow Direction : | Supported bidirectionally. Certain applications may require orientation, i.e., vents. Reverse flow only for low pressure applications. |
Sterilization: | May be autoclaved at 121°C for 20 minutes. Multiple autoclave cycles are possible. However, the responsibility for reuse is with the operator. The device should be protected from cross contamination. An integrity test should be performed after autoclaving.Compatible with EtO sterilization. |
Sealing : | Heat-fused |
Support System : | Polypropylene (PP) |
Dimensions: | 75 mm |
Product Name : | Polycap TF 75, 0.1 µm, with 3/8 in SB inlet and outlet (1 pc)
Polycap TF 75, 0.1 µm, with FNPT inlet and outlet (5 pcs) Polycap TF 75, 0.2 µm, with 3/8 in SB inlet and outlet (1 pc) Polycap TF 75, 0.2 µm, with 1/2 in SB inlet and outlet (1 pc) Polycap TF 75, 0.2 µm, with MNPT inlet and 3/8 in SB outlet (1 pc) Polycap TF 75, 0.2 µm, with MNPT inlet and outlet (5 pcs) Polycap TF 75, 0.2 µm, with FNPT inlet and outlet (5 pcs) Polycap TF 75, 0.45 µm, with 3/8 in SB inlet and outlet (1 pc) Polycap TF 75, 0.45 µm, with FNPT inlet and outlet (5 pcs) Polycap TF 75, 1.0 µm, with 1/2 in SB inlet and outlet (1 pc) |
Parameter | Polycap TF 150 |
---|---|
Housing : | Polypropylene (PP) |
Operating pressure max. : | 4.1 bar (60 psi) |
Vent : | On inlet |
Flow Direction : | Supported bidirectionally. Certain applications may require orientation, i.e., vents. Reverse flow only for low pressure applications. |
Sterilization: | May be autoclaved at 121°C for 20 minutes. Multiple autoclave cycles are possible. However, the responsibility for reuse is with the operator. The device should be protected from cross contamination. An integrity test should be performed after autoclaving.Compatible with EtO sterilization. |
Sealing : | Heat-fused |
Support System : | Polypropylene (PP) |
Dimensions: | 150 mm |
Product Name : | Polycap TF 150, 0.1 µm, with FNPT inlet and outlet (5 pcs)
Polycap TF 150, 0.2 µm, with 1.5 in sanitary inlet and outlet (5 pcs) Polycap TF 150, 0.2 µm, with FNPT inlet and outlet (5 pcs) Polycap TF 150, 0.45 µm, with FNPT inlet and outlet (5 pcs) Polycap TF 150, 1.0 µm, with FNPT inlet and outlet (5 pcs) |
Order now
To make your order, please contact us at info@polyscientific.com.my or call us at +6 06 3350 690