HI98192

Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Description

The HI98192 is a rugged, portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. This professional, waterproof meter complies with IP67 standards. The HI98192 is supplied complete with all accessories to perform an EC/TDS/ Resistivity/Salinity measurement packaged into a durable carrying case.

•  Ergonomic, One-Handed Operation
•  Four Ring Probe
•  Quick Connect

The HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.

HI98192 has an expanded conductivity range from 0.000 μS/cm to 1000 mS/cm actual conductivity (400 mS/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity, and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.

HI98192 can be used to perform all three stages of USPmethod required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.

   SPECIFICATIONS

  EC Range : 0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm;

100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)

  EC Resolution : 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
  EC Accuracy : ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
  EC Calibration : automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
  TDS Range : 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
  TDS Resolution : 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
  TDS Accuracy : ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
  Resistivity Range : 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
  Resistivity Resolution : 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
  Resistivity Accuracy : ±1% of reading (±10 Ω or 1 digit, whichever is greater)
  Salinity Range : % NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale – UNESCO 1966: 0.00 to 80.00 (ppt)
  Salinity Resolution: 0.1%; 0.01
  Salinity Accuracy : ±1% of reading
  Salinity Calibration: max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges
  Temperature Range : -20.0 to 120.0°C (-4.0 to 248.0°F)
  Temperature Resolution : 0.1°C (0.1°F)
  Temperature Accuracy : ±0.2°C; ±0.4°F (excluding probe error)
  Temperature Calibration : one or two points
  Temperature Compensation : noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
  Measurement Modes: autorange, autoend, lock and fixed range
  Reference Temperature: 15°C, 20°C and 25°C
  Temperature Coefficient : 0.00 to 10.00 %/°C
  TDS Factor : 0.40 to 1.00
  Electrode/Probe : HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9’) cable (included)
  Log-on-demand : 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
  Memorized Profiles : up to 10
  PC Connectivity : opto-isolated USB with optional HI 92000 software and micro USB cable
  Battery Type/Life : 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
  Auto-off : user selectable: 5, 10, 30, 60 min or can be disabled
  Environment : 0 to 50°C (32 to 122°F); RH 100% (IP67)
  Dimensions : 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
  Weight : 400 g (14.2 oz.)
  Ordering Information: HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL),

HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable,

1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case.

  Warranty                  : 2 years (probe 6 months)
  Notes                        : * The 0.001 µS/cm EC range and 0.1 MΩ•cm Resistivity range are not available with the 1.5 m cable probe.

Order now

To make your order, please contact us at  info@polyscientific.com.my or call us at +6 06 3350 690

Go to Top