HI96725

Chlorine, Cyanuric Acid, and pH Portable Photometer

Description

The HI96725 Chlorine, Cyanuric Acid, and pH Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine these three common water quality parameters using ready made reagents. The HI96725 offers many advanced features including the exclusive CAL Check™ function used for performance verification and calibration of the meter.

•  Automatic Shut Off
•  Built-in Timer
•  CAL Check™ Validation and Calibration

The HI96725 portable photometer is for the measurement of free and total chlorine, cyanuric acid, and pH. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

   ABSORBANCE SPECIFICATIONS

  Light Source   : tungsten lamp
  Light Detector  : silicon photocell with narrow band interference filter @ 525 nm

   NICKEL SPECIFICATIONS

  Nickel Range        : 0.00 to 7.00 g/L nickel
  Nickel Resolution : 0.01 g/L
  Nickel Accuracy   : ±0.07 g/L ±4% of reading
  Nickel Method      : adaptation of the photometric method

  pH SPECIFICATIONS

  pH Range        : 6.5 to 8.5 pH
  pH Resolution : 0.1 pH
  pH Accuracy   : ±0.1 pH
  pH Method      : phenol red method

  FREE CHLORINE AND TOTAL CHLORINE SPECIFICATIONS

  Chlorine Range       : 0.00 to 5.00 mg/L (ppm) Cl2
  Chlorine Resolution : 0.01 mg/L under 3.50 mg/L; 0.10 mg/L over 3.50 mg/L
  Chlorine Accuracy   : ±0.03 mg/L ±3% of reading
  Chlorine Method      : adaptation of the USEPA method and Standard Method 4500-Cl G

  CYANURIC ACID SPECIFICATIONS

  Cyanuric Acid Range        : 0 to 80 mg/L (ppm) cyanuric acid
  Cyanuric Acid Resolution : 1 mg/L
  Cyanuric Acid Accuracy   : ±1 mg/L ±15% of reading
  Cyanuric Acid Method      : adaptation of the turbidimetric method

  ADDITIONAL SPECIFICATIONS

  Auto-off                         : after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
  Environment                 : 0 to 50°C (32 to 122°F); RH max 95% non-condensing
  Weight                          : 360g (12.7oz.)
  Battery Type                  : 9V battery
  Dimensions                   : 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
  Ordering Information     : HI96725 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.
  Warranty                       : 2 years