pH, Free Chlorine and Total Chlorine, and Cyanuric Acid Portable Photometer
The HI96104 pH, Free and Total Chlorine, and Cyanuric Acid Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the pH, free and total chlorine, and cyanuric acid of water samples using ready made reagents. The HI96104 offers many advanced features including the exclusive CAL Check™ function used for performance verification and calibration of the meter.
• Automatic Shut Off
• Built-in Timer
• CAL Check™ Validation and Calibration
The HI96104 portable photometer is for the measurement of pH, free and total chlorine, and cyanuric acid. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
ABSORBANCE SPECIFICATIONS
Light Source : | tungsten lamp |
---|---|
Light Detector : | silicon photocell with narrow band interference filter @ 525 nm |
pH SPECIFICATIONS
pH Range : | 6.5 to 8.5 pH |
---|---|
pH Resolution : | 0.1 pH |
pH Accuracy : | ±0.1 pH |
pH Method : | phenol red method |
FREE CHLORINE AND TOTAL CHLORINE SPECIFICATIONS
Chlorine Range : | 0.00 to 5.00 mg/L (ppm) Cl2 |
---|---|
Chlorine Resolution : | 0.01 mg/L under 3.50 mg/L; 0.10 mg/L above 3.50 mg/L |
Chlorine Accuracy : | ±0.03 mg/L (ppm) ±3% of reading |
Chlorine Method : | adaptation of the USEPA DPD method 330.5 and Standard Method 4500-Cl G |
CYANURIC ACID SPECIFICATIONS
Cyanuric Acid Range : | 0 to 80 mg/L (ppm) cyanuric acid |
---|---|
Cyanuric Acid Resolution : | 1 mg/L |
Cyanuric Acid Accuracy : | ±1 mg/L ±15% of reading |
Cyanuric Acid Method : | adaptation of the turbidimetric method |
ADDITIONAL SPECIFICATIONS
Auto-off : | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
---|---|
Environment : | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight : | 360g (12.7oz.) |
Battery Type : | 9V battery |
Dimensions : | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
Ordering Information : | HI96104 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual. |
Warranty : | 2 years |