Three Range Portable TDS Meter
HI8734
Description
The HI8734 is a rugged, portable TDS meter designed for use in a wide variety of environmental conditions. It is supplied with a four-ring conductivity probe to allow for three ranges of measurement. TDS readings are adjusted with manual temperature compensation, assuring users of consistent and accurate measurements of total dissolved solids.
• Four-ring probe
• Manual Temperature Compensation
• Three measuring modes
The measurement of total dissolved solids (TDS) indicates the amount of ions dissolved in a solution. The Three Range Portable TDS Meter – HI8734 is suitable for use in the water conditioning industry, but particularly in the softening, demineralization, reverse osmosis, and drinking water applications. It offers three measurement ranges from 0.0 mg/L to 19.99 g/L with a ±1% FS accuracy. The HI76301D four-ring probe that is supplied with the meter allows for a wide range of measurements with a single sensor.
Features at-a-glance
Four-ring Probe
• The four-ring probe that comes with the HI8734 offers a versatile and accurate solution for TDS readings.
• Four ring technology allows for a larger range of measurement within a single probe, whereas two probe technology is somewhat limited in the range in which it can measure.
• The probe comes with a protective PVC sleeve that assures durability when taking measurements outdoors.
Manual Temperature Compensation
• Since temperature has such a dramatic effect on conductivity readings, having a meter that offers temperature compensated readings is invaluable.
• Once measured with an accurate thermometer, the temperature of the sample can be input on the meter using the temperature knob.
• The meter then accounts for the effects of temperature on the sample’s TDS reading in the range of 0 to 50°C (32 to 122°F).
• The temperature compensation coefficient, also known as β, is set at 2%/°C; this factor corrects the reading 2% for each degree Celsius change in the sample.
One-point Calibration
• The HI8734 can be calibrated at one point in a standard TDS solution.
• The calibration knob located on the face of the meter is easily adjusted to the correct calibration standard.
TDS Factor
• The TDS value in aqueous solutions is directly proportional to conductivity.
• The ratio between the two parameters depends on the solution being measured.
• The HI8734 has a set TDS factor of 0.5 that is common for many solutions, meaning that 1 μS/cm is equal to 0.5 mg/L (ppm) of TDS.
Three Measurement Ranges
• HI8734 offers three TDS measurement ranges. Each range has a dedicated button on the face of the meter, allowing users to easily switch between ranges when necessary.
• The meter is programmed to let the user know when their current reading is out of range, and a new range should then be selected.
SPECIFICATIONS
TDS Range : |
0.0 to 199.9 mg/L (ppm); 0 to 1999 mg/L (ppm); 0.00 to 19.99 g/L (ppt) |
---|---|
TDS Resolution : |
0.1 mg/L (ppm); 1 mg/L (ppm); 0.01 g/L (ppt) |
TDS Accuracy : |
±1% FS (excluding probe error) |
TDS Calibration : |
manual, one-point through TDS knob |
Temperature Compensation : |
manual from 0 to 50°C (32 to 122°F) with β = 2%/°C |
TDS Factor : |
0.5 |
Electrode/Probe : |
HI76301D four ring conductivity probe with DIN connector and 1 m (3.3’) cable (included) |
Battery Type/Life : |
9V / approximately 100 hours of continuous use |
Environment : |
0 to 50°C (32 to 122°F); RH max 95% |
Dimensions : |
145 x 80 x 36 mm (5.7 x 3.1 x 1.4”) |
Weight : |
230 g (8.1 oz) |
Ordering Information : |
HI8734 is supplied with HI76301D conductivity probe, HI70032 1382 mg/L (ppm) calibration solution sachet, battery, and instruction manual. |
Warranty : |
2 years (probe 6 months) |
Order now
To make your order, please contact us at info@polyscientific.com.my or call us at +6 06 3350 690