HI83414-01

EPA Compliant Benchtop Turbidity and Chlorine Meter

Description

The HI83414 is a high accuracy turbidity and chlorine benchtop meter. This meter is a combination of a nephelometer and photometer to measure the most important parameters in drinking water: turbidity and chlorine. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards and NIST traceable secondary chlorine standards used for calibration and performance verification. The HI83414 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements. For chlorine measurements an adaptation of EPA Method 330.5 and Standard Method 4500-Cl G is used.

•  Compliant to EPA Methods
•  Up to ±2% of reading plus 0.02 NTU accuracy
•  USB for data transfer

  TURBIDITY SPECIFICATIONS

 Non-Ratio Mode Range : 0.00 to 9.99; 10.0 to 40.0 NTU; 0.0 to 99.9; 100 to 268 Nephelos; 0.00 to 9.80 EBC
 Non-Ratio Mode Resolution : 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC
 Ratio Mode Range : 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU; 0.0 to 99.9; 100 to 26800 Nephelos; 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
 Ratio Mode Resolution : 0.01; 0.1; 1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC
 Range Selection : automatic
 Accuracy (@25ºC/77ºF) : ±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC); ±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC)
 Repeatability : ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater
 Stray Light : < 0.02 NTU (0.15 Nephelos; 0.01 EBC)
 Light Detector : silicon photocell
 Method : nephelometric method (90°) or ratio nephelometric method (90° & 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B
 Measuring Mode : normal, average, continuous
 Turbidity Standards : < 0.1, 15, 100, 750 and 2000 NTU
 Calibration : two, three, four, or five-point calibration

  FREE AND TOTAL CHLORINE SPECIFICATIONS

 Free and Total Chlorine Range        : 0.00 to 5.00 mg/L (ppm)
 Free and Total Chlorine Resolution  : 0.01 mg/L (ppm) from 0.00 to 3.50 mg/L (ppm); 0.10 above 3.50 mg/L (ppm)
 Free and Total Chlorine Accuracy    : ±0.02 mg/L @ 1.00 mg/L
 Light Detector                                  : silicon photocell with 525 nm narrow band interference filter
 Method                                            : adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G.
 Standards                                        : 1.00 mg/L (ppm) free chlorine; 1.00 mg/L (ppm) total chlorine
 Calibration                                       : one-point calibration

SPECIFICATIONS

 Battery Type / Life : Auto-shut off after 15 min
 Light Source :
tungsten filament lamp / greater than 100,000 readings
 Display : 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
 Log Memory : 200 records
 Connectivity : USB
 Environment : 0 to 50°C (32 to 122°F), RH max 95% non-condensing
 Power Supply : 115/130 VAC; 50/60 Hz
 Dimensions : 230 x 200 x 145 mm (9.0 x 7.9 x 5.7”)
 Weight : 2.5 kg (88 oz.)
 Ordering Information : HI83414 is supplied with sample cuvettes (5) with caps, calibration cuvettes for turbidity and chlorine, silicone oil, cuvette wiping cloth, scissors, power cord, and instruction manual.
 Warranty : 2 years

Order now

To make your order, please contact us at  info@polyscientific.com.my or call us at +6 06 3350 690

Go to Top