HI96726

Nickel High Range Portable Photometer

Description

The HI96726 Nickel High Range Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the concentration of nickel within a 0.00 to 7.00 g/L range using the HI93726-0 ready made reagents. The HI96726 offers many advanced features including the exclusive CAL Check™function used for performance verification and calibration of the meter.

•  Automatic Shut Off
•  Built-in Timer
•  CAL Check™ Validation and Calibration

The HI96726 portable photometer is for the high range measurement of nickel. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

  Features/Benefits:
Auto-shut off
•  Automatic shut off after 10 minutes of non-use when the meter is in measurement mode.
•  Prevents wastage of batteries in the event the meter is accidentally not turned off.

  Built in timer
•  Ensures the appropriate reaction time is used for the chemical reaction. At the end of the timer the meter will automatically take the reading. This feature ensures consistency across multiple users.

  CAL Check
•  Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.

  Cooling Lamp Indicator
•  It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light.
•  This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.

  Error messages
•  Messages on display alerting to problems including no cap, over range and under range readings, and light source error.

  GLP
•  Records the date of the last user calibration performed.

  Indexing indent on meter
•  The meter has an indent that allows for a lock and key fit with the cuvette cap.
•  This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.

  Battery status indicator
The instrument has a battery level indicator to display reaming life as follows:
•  3 lines for 100 % capacity
•  2 lines for 66 % capacity
•  1 line for 33 % capacity
•  Battery icon blinks when the capacity is less than 10 %.

   ABSORBANCE SPECIFICATIONS

  Light Source   : tungsten lamp
  Light Detector  : silicon photocell with narrow band interference filter @ 575 nm

   NICKEL SPECIFICATIONS

  Nickel Range        : 0.00 to 7.00 g/L nickel
  Nickel Resolution : 0.01 g/L
  Nickel Accuracy   : ±0.07 g/L ±4% of reading
  Nickel Method      : adaptation of the photometric method

  ADDITIONAL SPECIFICATIONS

  Auto-off                         : after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
  Environment                 : 0 to 50°C (32 to 122°F); RH max 95% non-condensing
  Weight                          : 360g (12.7oz.)
  Battery Type                  : 9V battery
  Dimensions                   : 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
  Ordering Information     : HI96726 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.
  Warranty                       : 2 years