HI93102

Portable Multiparameter Turbidity and Ion Specific Meter

Description

The HI93102 is a portable multiparameter meter that measures turbidity, free and total chlorine, cyanuric acid, pH, iodine, bromine, and low range iron. This meter combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the turbidity after calibration with AMCO-AEPA-1 standards; determination of free chlorine, total chlorine, cyanuric acid, pH, iodine, bromine, and low range iron is reliable and consistent with the use of ready made reagents.
  •  Custom Calibration Points
•  EPA Compliant Turbidity Method
•  Logging Mode

The most important parameters needed for water analysis, especially in drinking water, can be measured with Hanna’s HI93102 portable meter. This instrument not only measures turbidity, but also free and total chlorine, cyanuric acid, pH, iodine, bromine, and low range iron. Measurements are made quickly and accurately through a sophisticated, yet easy-to-use microprocessor. Users can select between pre-programmed calibration values or calibration points can be customized at a specified concentration or relative absorbance of the sample.

The HI93102 offers many features that appeal to use in the field as well as in laboratory settings. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length. Up to 25 measured samples can be stored in memory, together with time and date. Miniaturization of the electronics has made it possible to o‰ffer unsurpassed accuracy and quality in a portable unit weighing just one pound.

   TURBIDITY SPECIFICATIONS

  Turbidity Range         : 0.00 to 50.0 NTU
  Turbidity Resolution  : 0.01 (0.00 to 9.99); 0.1 NTU (10.0 to 50.0)
  Turbidity Accuracy    : ±0.5 NTU or ±5% of reading (whichever is greater)
  Turbidity Calibration : two-point; selectable between 0.00 – 50.0 FTU (0.00 and 20.0 FTU recommended)

   BROMINE SPECIFICATIONS

  Bromine Range        : 0.00 to 8.00 mg/L (ppm)
  Bromine Resolution : 0.01 mg/L (ppm)
  Bromine Accuracy   : ±0.08 mg/L (ppm); ±3% of reading

   FREE AND TOTAL CHLORINE SPECIFICATIONS

  Chlorine Range        : Free: 0.00 to 2.50 mg/L (ppm); Total: 0.00 to 3.50 mg/L (ppm)
  Chlorine Resolution : 0.01 mg/L (ppm)
  Chlorine Accuracy   : ±0.03 mg/L (ppm); ±3% of reading

   CYANURIC ACID

  Cyanuric Acid Range        : 0 to 80 mg/L (ppm)
  Cyanuric Acid Resolution : 1 mg/L (ppm)
  Cyanuric Acid Accuracy   : ±1 mg/L (ppm); ±15% of reading

   IODINE SPECIFICATIONS

  Iodine Range        : 0.0 to 12.5 mg/L (ppm)
  Iodine Resolution : 0.1 mg/L (ppm)
  Iodine Accuracy   : ±0.1 mg/L (ppm); ±5% of reading

   IRON LR SPECIFICATIONS

  Iron Range        : 0.00 to 1.00 mg/L (ppm)
  Iron Resolution : 0.01 mg/L (ppm)
  Iron Accuracy   : ±0.02 mg/L (ppm); ±3% of reading

   pH SPECIFICATIONS

  pH Range        : 5.9 to 8.5 pH
  pH Resolution : 0.1 pH
  pH Accuracy   : ±0.1 pH

   GENERAL SPECIFICATIONS

  Light Detector            : silicon photocell (2)
  Light Source / Life     : pure green LED
  Battery Type / Life     : 1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements;

automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes of non-use

  Environment              : 0 to 50°C (32 to 122°F); RH max 95% (non condensing)
  Dimensions                : 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’)
  Weight                       : 510 g (1.1 lb.)
 Ordering Information  : HI93102 is supplied with measurement cuvette cap, batteries and instruction manual.
  Warranty                    : 2 years

Order now

To make your order, please contact us at  info@polyscientific.com.my or call us at +6 06 3350 690

Go to Top