HI9033
Description
The HI9033 is a rugged, portable EC meter designed for use in a wide variety of environmental conditions. It is supplied with a four-ring conductivity probe that can measure across four ranges. Conductivity readings are adjusted with Automatic Temperature Compensation (ATC), assuring users of consistent and accurate conductivity measurements.
• Automatic Temperature Compensation
• Four-ring probe
• Four measuring ranges
The portable HI9033 EC meter is suitable for use in a variety of applications. It offers four measurement ranges from 0.0 µS/cm to 199.9 mS/cm with a ±1% FS accuracy. The HI76302W four-ring conductivity probe that is supplied with the meter allows for a wide range of measurements with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The probe also features a built-in temperature sensor to allow for Automatic Temperature Compensation from 0 to 50°C (32 to 122°F).
Features at-a-glance
Automatic Temperature Compensation
• Since temperature has such a dramatic effect on conductivity readings, having a meter that offers temperature compensated readings is invaluable.
• The probe of the HI9033 features a built-in temperature sensor that automatically accounts for the effects of temperature on a sample’s conductivity reading in the range of 0 to 50°C (32 to 122°F).
• The temperature compensation coefficient, also known as β, is set at 2%/°C; this factor corrects the conductivity reading 2% for each degree Celsius change in the sample.
Battery Error Prevention System (BEPS)
• The Battery Error Prevention System detects when the batteries become too weak to ensure reliable measurements.
Four-ring Probe
• The four-ring probe that comes with the HI9033 offers a versatile and accurate solution for conductivity readings.
• Four ring technology allows for a larger range of measurement within a single probe, whereas other meters with two probe technology is somewhat limited in the range in which they can measure.
Four Measurement Ranges
• HI9033 offers four conductivity measurement ranges. Each range has a dedicated button on the face of the meter, allowing users to easily switch between ranges when necessary.
• The meter is programmed to let the user know when their current reading is out of range, and a new range should then be selected.
One-point Calibration
• The HI9033 can be calibrated at one point in a standard conductivity solution.
• The calibration trimmer located on the top of the meter is easily adjusted to the correct calibration standard.
SPECIFICATIONS
EC Range : | 0.0 to 199.9 μS/cm; 0 to 1999 μS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm |
---|---|
EC Resolution : | 0.1 μS/cm; 1 μS/cm; 0.01 mS/cm; 0.1 mS/cm |
EC Accuracy : | ±1% FS (excluding probe error) |
EC Calibration : | manual, one point |
Temperature Compensation : | automatic, 10 to 50°C (50 to 122°F) with β = 2%/°C |
Electrode/Probe : | HI76302W conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included) |
Battery Type/Life : | 9V / approximately 100 hours of continuous use |
Environment : | 0 to 50°C (32 to 122°F); RH max 95% |
Dimensions : | 196 x 80 x 60 mm (7.7 x 3.1 x 2.4’’) |
Weight : | 425 g (0.9 lb) |
Ordering Information : | HI9033 is supplied with HI76302W conductivity probe, calibration screwdriver, battery, instruction manual and rugged carrying case. |
Warranty : | 2 years (probe 6 months) |
Order now