HI8733

Multi-range EC Meter

Description

The HI8733 is a durable, portable EC meter designed for use in areas of production and quality control. It is supplied with a four-ring conductivity probe to allow for four ranges of measurement. Conductivity readings are adjusted with Automatic Temperature Compensation (ATC), assuring users of consistent and accurate measurements.

•  Automatic Temperature Compensation
•  Four-ring probe
•  Four measuring modes

The portable Multi-range EC Meter – HI8733 is suitable for use in a variety of applications. It offers four measurement ranges from 0.0 µS/cm to 199.9 mS/cm with a ±1% FS accuracy. The HI76302W four-ring conductivity probe that is supplied with the meter allows for a wide range of measurements with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The probe also features a built-in temperature sensor to allow for Automatic Temperature Compensation from 0 to 50°C (32 to 122°F) and an adjustable β from 0 to 2.5%/°C.

Features at-a-glance
Adjustable Temperature Coefficient
•  As the temperature of a solution increases or decreases, the conductance becomes higher or lower, respectively.
•  The temperature compensation coefficient, also known as β, is the factor that adjusts for the temperature of a solution to ensure an accurate reading is achieved.
•  The HI8733 allows for an adjustable β to be set from 0 to 2.5%/°C; this factor corrects the conductivity reading by the set percentage for each degree Celsius change in the sample.

  Automatic Temperature Compensation
•  Since temperature has such a dramatic effect on conductivity readings, having a meter that offers temperature compensated readings is invaluable.
•  The probe of the HI8733 features a built-in temperature sensor that automatically accounts for the effects of temperature on a sample’s conductivity reading in the range
of 0 to 50°C (32 to 122°F).

  Four Measurement Ranges
•  HI8733 offers four conductivity measurement ranges. Each range has a dedicated button on the face of the meter, allowing users to easily switch between ranges
when necessary.
•  The meter is programmed to let the user know when their current reading is out of range, and a new range should then be selected.

  Four-ring Probe
•  The four-ring probe that comes with the HI8733 offers a versatile and accurate solution for conductivity readings.
•  Four ring technology allows for a larger range of measurement within a single probe, whereas two probe technology is somewhat limited in the range in which it can measure.
•  The probe comes with a protective PVC sleeve that assures durability when taking measurements outdoors.

  One-point Calibration
•  The HI8733 can be calibrated at one point in a standard conductivity solution.
•  The calibration knob located on the top of the meter is easily adjusted to the correct calibration standard.

   SPECIFICATIONS

  EC Range : 0.0 to 199.9 μS/cm; 0 to 1999 μS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm
  EC Resolution : 0.1 μS/cm; 1 μS/cm; 0.01 mS/cm; 0.1 mS/cm
  EC Accuracy : ±1% FS (excluding probe error)
  EC Calibration : manual, one-point through EC knob
  Temperature Compensation : automatic, 0 to 50°C (32 to 122°F) with β adjustable from 0 to 2.5%/°C
  Electrode/Probe : HI76302W conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included)
  Battery Type/Life : 9V / approximately 100 hours of continuous use
  Environment : 0 to 50°C (32 to 122°F); RH max 95%
  Dimensions : 145 x 80 x 36 mm (5.7 x 3.1 x 1.4”)
  Weight : 230 g (8.1 oz)
  Ordering Information : HI8733 is supplied with HI76302W conductivity probe, 12880 μS/cm HI70030 calibration solution sachet (1), battery, and instruction manual.
  Warranty : 2 years (probe 6 months)