Multi-Range EC Meter with Manual Temperature Compensation
HI8633
Description
The HI8733 is a durable, portable EC meter designed for use in areas of production and quality control. It is supplied with a four-ring conductivity probe to allow for four ranges of measurement. Conductivity readings are adjusted with Automatic Temperature Compensation (ATC), assuring users of consistent and accurate measurements.
• Automatic Temperature Compensation
• Four-ring probe
• Four measuring modes
The portable HI8633 EC meter is suitable for use in a variety of applications. It offers four measurement ranges from 0.0 µS/cm to 199.9 mS/cm with a ±1% FS accuracy. The HI76301W four-ring conductivity probe that is supplied with the meter allows for a wide range of measurements with a single sensor. The four-ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI8633 offers manual temperature compensation from 0 to 50°C (32 to 122°F) and a fixed β at 2%/°C.
Features/Benefits:
Fixed Temperature Coefficient
• As the temperature of a solution increases or decreases, the conductance becomes higher or lower, respectively.
• The temperature compensation coefficient, also known as β, is the factor that adjusts for the temperature of a solution to ensure an accurate reading is achieved.
• The HI8633 is programmed with a fixed β at 2%/°C; this factor corrects the conductivity reading by 2% for each degree Celsius change in the sample.
Four Measurement Ranges
• HI8633 offers four conductivity measurement ranges. Each range has a dedicated button on the face of the meter, allowing users to easily switch between ranges when necessary.
• The meter is programmed to let the user know when their current reading is out of range, and a new range should then be selected.
Four-ring Probe
• The HI76301D four-ring probe that comes with the HI8633 offers a versatile and accurate solution for conductivity readings.
• Four-ring technology allows for a larger range of measurement within a single probe, whereas two probe technology is somewhat limited in the range in which it can measure.
• The probe comes with a protective PVC sleeve that assures durability when taking measurements outdoors.
Manual Temperature Compensation
• Since temperature has such a dramatic effect on conductivity readings, having a meter that offers temperature compensated readings is invaluable.
• The HI8633 allows users to adjust the temperature of the measurement solution through a knob on the face of the meter.
• The adjustment accounts for the effects of temperature on a sample’s conductivity reading in the range of 0 to 50°C (32 to 122°F).